TES Digital AC Clamp Meter TES-3040H
TES-3040H
Digital AC Clamp Meter
Product Features
-
3-3/4 Digital LCD with bar-graph
-
Auto-Ranging on Volt, Ohm, Current, Frequency measurements
-
Auto-power off
-
Data Hold mode
-
MAX/MIN Hold mode
-
Zero Adjustment/Relative Reading
Category: Clamp Meter
Description
MEASUREMENT SPECIFICATIONS:
AC Current (Autorange & Manual): Low Pass Filter
Range
|
Resolution
|
Accuracy
|
Overload protection
|
Frequency
Response
|
400A
|
0.1A
|
±(2% + 10)
|
1100A
|
40~450 Hz
|
1000A
|
1A
|
Conversion type: AC coupled, TRMS measurement.
Additional Crest Factor Errors (non – sinecure)
Crest Factor
|
Error (% of reading)
|
1 – 3
|
0.5%
|
3 – 5
|
3%
|
5 – 7
|
6%
|
Response time: 5 seconds max, to rated accuracy within selected range.
INFLUENCE OUANTITY
Influence quantity
|
Limits of variation
|
Measured quantity
|
Tolerance
|
Position of conductor in the clamp conductor’s diameter: 20mm
|
In relation to the center
|
Amps
|
±(1%+5)
|
DC Voltage (Autorange & Manual)
Range
|
Resolution
|
Accuracy
|
Input Impedance
|
Overload protection
|
400mV
|
0.1mV
|
±(0.75% + 2)
|
≒ 11MΩ
|
600Vrms
|
4V
|
0.001V
|
≒ 10MΩ
|
||
40V
|
0.01V
|
|||
400V
|
0.1V
|
|||
600V
|
1V
|
Response time: 3 seconds max. to rated accuracy within selected range.
AC Voltage (Autorange & Manual): Low Pass Filter
Range
|
Resolution
|
Accuracy
|
Input impedance
|
Overload protection
|
Frequency
Response
|
4V
|
0.001V
|
±(1.2%+5)
|
≒ 11MΩ
|
600Vrms
|
40~450 Hz
|
40V
|
0.01V
|
≒ 10MΩ
|
|||
400V
|
0.1V
|
||||
600V
|
1V
|
±(1.5%+5)
|
Conversion type: AC coupled, TRMS measurement.
Additional Crest Factor Errors (non – sinecure)
Crest Factor
|
Error (% of reading)
|
1 – 3
|
0.5%
|
3 – 5
|
3%
|
5 – 7
|
6%
|
Response time: 5 seconds max, to rated accuracy within selected range.
Frequency (Hz) (Autorange for Voltage)
Range
|
Resolution
|
Accuracy
|
Sensitivity
|
Overload protection
|
100Hz
|
0.01Hz
|
±(0.1% + 2)
|
100mV
|
600Vrms
|
1KHz
|
0.1Hz
|
|||
5KHz
|
0.001KHz
|
Frequency (Hz) (Autorange for Current)
Range
|
Resolution
|
Accuracy
|
Sensitivity
|
Overload protection
|
100Hz
|
0.01Hz
|
±(0.5% + 5)
|
5A
|
1100A
|
1KHz
|
0.1Hz
|
Resistance (Ω) (Autorange & Manual)
Range
|
Resolution
|
Accuracy
|
Open circuit
Voltage
|
Overload protection
|
400Ω
|
0.1Ω
|
±(1% + 5)
|
≦ 0.5 VDC
|
600Vrms
|
4KΩ
|
0.001KΩ
|
±(1% + 3)
|
||
40KΩ
|
0.01KΩ
|
|||
400KΩ
|
0.1KΩ
|
|||
4MΩ
|
0.001MΩ
|
|||
40MΩ
|
0.01MΩ
|
±(1.5% + 3)
|
Audible continuity
Range
|
Continuity beeper
|
Open Circuit Voltage
|
Overload protection
|
≦ 40Ω
|
≦ 0.5V
|
600Vrms
|
Diode test
Range
|
Resolution
|
Accuracy
|
Overload protection
|
|
0.001V
|
±(1%+2)
|
600Vrms
|
Max. open circuit Voltage: 3.2V
Max. short circuit Current: 1.0mA (typical).
SPECIFICATIONS:
Numerical Display :3-3/4 digit liquid crystal display (LCD) maximum reading 3999.
Range Selection :All ranges are selected by a single range switch.
Over Range Indication :LCD will show a “OL” flashing
in the highest position accompanied with a continuous beeping.
in the highest position accompanied with a continuous beeping.
(except for ranges of 1000A AC, and 600VDC 600VAC ).
Low Battery Indication :The is displayed when the battery voltage drops
below the operating voltage.
Sampling Rate :20 times/sec ( Barograph )
2 times/sec(Digital Display)
Power Source :one 006p 9V or IEC 6F22 or NEDA 1604 Battery.
Battery Life :100hr approx. (Alkaline)
Polarity :Automatic polarity ” – ” display for negative input.
Auto power off time :Approx. 30 minutes
Operating Temperature :0°C to 50°C(32°F to 122°F) and Humidity below 80%RH
Storage Temperature :-10°C to 60°C(14°F to 140°F) and Humidity below 70%RH
Dimensions :239(L)×66(W)×34(H)mm
Weight :Approx. 430g
Accessories :Instruction manual, Battery, Test leads, Carry Case.
Related products
Clamp Meter
Clamp Meter
Clamp Meter
Clamp Meter
Clamp Meter
Clamp Meter
Clamp Meter