TES-1384 4 Input Thermometer / Datalogger
Product Features:
- Confined Input Protection of 350Vp-p between any two data sources.
- Profoundly exact thermometer with thermocouple K, J, E, T, R, S, N, L, U, B, C sorts.
4 information capability T1/T2/T3/T4 temperature show. - Programmable Hi – Lo caution for 4 data sources. Show of MAX, MIN, MAX-MIN and AVG upsides of 4 information sources.
- Autonomous Input Setup (sort of thermocouple,Hi – Lo alert qualities).
- Memory and Read capability (99 sets) 512KB auto datalogging capacity(4 input:36000 sets/1 information: 100000 sets USB interface.
Categories: Climatic/Environment Inspection, Thermometer
Description
0.1°C, 0.1°F Resolution, Accuracy is of reading.
Type | °C | °F | ||
Range | Accuracy | Range | Accuracy | |
-200 ~ -150 | ±3.0°C | -328 ~ -238 | ±5.4°F | |
K | -150 ~ -100
-100 ~ 999.9 |
±2.0°C
±0.05% ±1.0°C |
-238 ~ -148
-148 ~ 999.9 |
±3.6°F
±0.05% ±1.8°F |
1000 ~ 1370 | ±0.2% ±1.0°C | 1000 ~ 2498 | ±0.2% ±1.8°F | |
J |
-200 ~ -100
-100 ~ 100 100 ~ 999.9 |
±2.5°C
±1.5°C ±0.05% ±1.0°C |
-328 ~ -148
-148 ~ 212 212 ~ 999.9 1000 ~ 1832 |
±4.5°F
±2.7°F ±0.05% ±1.8°F ±0.2% ±1°F |
E |
-150 ~ -100
-100 ~ 760 |
±3.0°C
±0.05% ±1.0°C |
-238 ~ -148
-148 ~ 999.9 1000 ~ 1400 |
±5.4°F
±0.05% ±1.8°F ±0.2% ±1°F |
-200 ~ -150 | ±3.0°C | -328 ~ -238 | ±5.4°F | |
T | -150 ~ -100 | ±0.15% ±2.5°C | -238 ~ -148 | ±0.15% ±4.5°F |
-100 ~ 400 | ±0.1% ±1.0°C | -148 ~ 752 | ±0.1% ±1.8°F | |
0 ~ 100 | ±5.0°C | 32 ~ 212 | ±9.0°F | |
R/S | 100 ~ 300
300 ~ 999.9 |
±3.0°C
±0.05% ±2.0°C |
212 ~ 572
572 ~ 999.9 |
±5.4°F
±0.05% ±3.6°F |
1000 ~ 1600 | ±0.25% ±2.0°C | 1000 ~ 2912 | ±0.25% ±3.6°F | |
N | 0 ~ 999.9 | ±0.1% ±1.0°C | 32 ~ 999.9 | ±0.1% ±1.8°F |
1000 ~ 1300 | ±0.2% ±1.0°C | 1000 ~ 2372 | ±0.2% ±1.8°F | |
L | -200 ~ 900 | ±0.1% ±1.0°C | -328 ~ 999.9 | ±0.1 % ±1.8°F |
1000 ~ 1652 | ±0.2% ±1°F | |||
U | 0 ~ 600 | ±0.1% ±1.0°C | 32 ~ 999.9 | ±0.1% ±1.8°F |
1000 ~ 1112 | ±0.2% ±1°F | |||
B | 600 ~ 999.9 | ±0.05% ±2.0°C | 1112 ~ 1831 | ±0.05% ±3.6°F |
1000 ~ 1760 | ±0.1% ±2.0°C | 1832 ~ 3200 | ±0.1% ±3.6°F | |
C | 0 ~ 999.9 | ±0.1% ±1.5°C | 32 ~ 999.9 | ±0.1% ±2.7°F |
1000 ~ 1760 | ±0.2% ±1.5°C | 1000 ~ 3200 | ±0.2% ±2.7°F |
Temperature Coefficient | 0.01% of reading + 0.1°C per °C (0.2°F per °F) outside
the specified +18°C to 28°C (+64°F to +82°F) range |
Isolated Input Protection
between any two inputs |
350Vp-p |
Sampling Rate | One time per 2 seconds |
Operating / Storage Conditions | 0°C ~ 50°C < 80% RH , -10°C ~ 60°C < 70%RH |
Power Source | 6 pcs size AA Alkaline battery |
Battery Life | Approx. 55 hours. (Alkaline battery) |
Size | 18.7(L) × 7.3(W) × 5.3(T) cm / 7.3”(L) × 2.9”(W) × 2.1”(T) |
Weight | Approx. 405g with batteries |
Accessories | Instruction manual, Alkaline battery, USB cable, Software CD,
Carrying case, K-type thermocouples (1M x1). |
Optional Accessories | K-type thermocouples:1M x 1, 3M x 1, 5M x 1 |
Related products
Climatic/Environment Inspection
Climatic/Environment Inspection
Climatic/Environment Inspection
Climatic/Environment Inspection
Climatic/Environment Inspection
Climatic/Environment Inspection
Climatic/Environment Inspection
Climatic/Environment Inspection