Hanna Instruments HI99181 Skin pH Portable Meter
- Automatic Temperature Compensation
- Automatic Two-Point Calibration
- Waterproof
Glass Body
The glass body of the HI14143/50 is chemically resistant and quick to reach thermal equilibrium, allowing for a faster, more stable response.
Flat Tip
The flat tip sensing bulb allows for the direct surface measurement of skin. Maximum surface contact is achieved with this specialized tip shape.
Open Junction Reference
The open junction design consists of a solid gel interface (viscolene) between the sample and internal Ag/AgCl reference. This interface not only prevents silver from entering the sample, but also makes it impermeable to clogging, resulting in a fast response and stable reading.
Built-in Temperature Sensor
Errors in calibration and measurement are eliminated with the Automatic Temperature Compensation provided by the integrated temperature sensor.
Features at-a-glance
Waterproof – The HI99181 is a waterproof meter rated IP67 for immersion in up to one meter of water for 30 minutes.
Automatic Calibration – One or two-point calibration is automatic to two selectable buffer sets.
Automatic Temperature Compensation – An integrated temperature sensor allows for automatic temperature compensation of pH measurements.
Sensor Check – Using the pH‐mV range the user can check the sensor status by reading the mV reading in fresh buffers. At room temperature (25 oC/77oF) the reading should be +/- 30 mV in pH 7.01 and greater than 150 mV difference between pH 7.01 and 4.01.
Multi-Level LCD Display – The split-level LCD displays both pH and temperature readings, along with indicators for reading stability, battery percentage, and probe condition.
Probe Condition Indicator – The probe condition indicator is based on the offset and slope characteristic of the electrode. There are 5 bars ranging from all 5 indicating the probe is in excellent condition and 1 bar indicating the probe should be cleaned or replaced.
Battery Error Prevention System – The meter will automatically shut off if there isn’t enough power to obtain an accurate measurement.
Battery Life Indicator – The battery percent level is displayed at start up alerting the user to the remaining battery power that is available.
Related products
Biochemical Oxygen Demand (BOD)
Hanna Instruments HI98193 Waterproof Portable Dissolved Oxygen and BOD Meter
Oxidation-Reduction Potential (ORP)
Hanna Instruments HI991003 Waterproof Portable pH/pH-mV/ORP/Temperature Meter with Sensor Check™
Dissolved Oxygen (DO)
Hanna Instruments HI98199 Multiparameter Portable pH/EC/DO Waterproof Meter
Electrical Conductivity (EC)
Dissolved Oxygen (DO)
Hanna Instruments HI98198 opdo Waterproof Optical Dissolved Oxygen Meter