Hanna Instruments HI98196 Multiparameter pH/ORP/DO/Pressure/Temperature Waterproof Meter
The HI98196 is a portable, waterproof multiparameter meter that measures five measured and two calculated water quality parameters out of a possible seven. The pH, ORP, dissolved oxygen, and temperature may all be measured using the microprocessor-based multi-sensor probe.
The meter receives readings from the probe digitally and may display and log the data points. The use of digital communication enables the transfer of data via cables up to 100 meters long without any background noise. The entire system is simple to install and simple to operate.
- Multi-Parameter Display
- Multi-sensor Probe
- USB Connection
SKU | HI98196-web |
---|---|
Product Name | Multiparameter pH/ORP/DO/Pressure/Temperature Waterproof Meter – HI98196 |
Quote Required | Yes |
pH Range | 0.00 to 14.00 pH |
pH Resolution | 0.01 pH |
pH Accuracy | ±0.02 pH |
pH Calibration | automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer |
ORP Range | ±2000 mV |
ORP Resolution | 0.1 mV |
ORP Accuracy | ±1.0 mV |
ORP Calibration | automatic at one custom point (relative mV) |
mV Range | ±600.0 mV |
mV Resolution | 0.1 mV |
mV Accuracy | ±0.5 mV |
Dissolved Oxygen Measurement Type | galvanic |
Dissolved Oxygen Range | 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L) |
Dissolved Oxygen Resolution | 0.1%; 0.01 ppm (mg/L) |
Dissolved Oxygen Accuracy | 0.0 to 300.0% saturation |
Dissolved Oxygen Calibration | automatic one or two point at 100% saturation (8.26 mg/L) and 0% saturation (0 mg/L). |
Dissolved Oxygen Temperature Compensation | automatic from 0.0 to 50.0 °C (32.0 to 122.0 °F) |
Barometric Pressure Compensation | automatic from 450 to 850 mmHg |
Salinity Compensation | automatic from 0 to 70 g/L |
Temperature Range | -5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K |
Temperature Resolution | 0.01 K, 0.01 °C, 0.01 °F |
Temperature Accuracy | ±0.15 °C; ±0.27 °F; ±0.15 K |
Temperature Calibration | automatic at one custom point |
Temperature Compensation | automatic from -5 to 55 °C (23 to 131 °F) |
Logging Memory | 45,000 records (continuous logging or log-on-demand of all parameters) |
Logging Interval | one second to three hours |
Connectivity | USB to PC with HI9298194 Hanna software installed |
Battery Type/Life | 1.5V AA batteries (4) / approximately 360 hours of continuous use without backlight (50 hours with backlight) |
Environment | 0 to 50°C (32 to 122°F); RH 100% (IP67) |
Dimensions | 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) |
Weight | 400 g (14.2 oz.) |
Ordering Information | HI98196 is supplied with HI7698196 probe, HI7698194-1 pH/ORP sensor, HI7698194-2 DO sensor, HI 76981942 Probe maintenance kit (HI 7042S DO electrolyte solution, DO membrane caps (5), O-rings for sensors (5), syringe with grease to lubricate the O-rings), HI9298194 Hanna PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate, and rugged carrying case with custom thermoformed insert. |
Atmospheric Pressure Range | 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa |
Atmospheric Pressure Resolution | 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
Atmospheric Pressure Accuracy | ±3 mm Hg within ±15% from calibration point |
Atmospheric Pressure Calibration | automatic at one custom point |
Related products
Electrical Conductivity (EC)
Oxidation-Reduction Potential (ORP)
Hanna Instruments HI991003 Waterproof Portable pH/pH-mV/ORP/Temperature Meter with Sensor Check™
Electrical Conductivity (EC)
Electrical Conductivity (EC)
Hanna Instruments HI991300 Portable Waterproof pH/EC/TDS Meter (Low Range)
Dissolved Oxygen (DO)
Hanna Instruments HI98198 opdo Waterproof Optical Dissolved Oxygen Meter