Specifications
CANNON-FENSKE OPAQUE
ASTM D-445-446, ASTM D2515, ISO 3104-3105 and UNE 400313 Cannon-Fenske Opaque Viscometers (reverse flow type) are used for dark Newto- nian liquids; especially suitable for liquids so dark in colour that cannot be seen in a Cannon-Fenske routine viscometer. Also used to study shearing stress and shearing rate. Sample volume: aprox. 12 ml. Precision: ±0.3%. Value indicated at 40ºC and 100ºC in both bulbs.
| CODE |
DESCRIPTION |
VISCOSITY RANGE |
MATERIAL |
CONSTANT K APPROX. |
INCLUDED |
| CV004-101 |
Cannon-Fenske Opaque size 25 |
0.4 – 2 cSt |
Glass |
0.002 |
Capillary Tube – Calibration Certificate |
| CV004-102 |
Cannon-Fenske Opaque size 50 |
0.8 – 4 cSt |
Glass |
0.004 |
Capillary Tube – Calibration Certificate |
| CV004-103 |
Cannon-Fenske Opaque size 75 |
1.6 – 8 cSt |
Glass |
0.008 |
Capillary Tube – Calibration Certificate |
| CV004-104 |
Cannon-Fenske Opaque size 100 |
3 – 15 cSt |
Glass |
0.015 |
Capillary Tube – Calibration Certificate |
| CV004-105 |
Cannon-Fenske Opaque size 150 |
7 – 35 cSt |
Glass |
0.035 |
Capillary Tube – Calibration Certificate |
| CV004-106 |
Cannon-Fenske Opaque size 200 |
20 – 100 cSt |
Glass |
0.1 |
Capillary Tube – Calibration Certificate |
| CV004-107 |
Cannon-Fenske Opaque size 300 |
50 – 200 cSt |
Glass |
0.25 |
Capillary Tube – Calibration Certificate |
| CV004-108 |
Cannon-Fenske Opaque size 350 |
100 – 500 cSt |
Glass |
0.5 |
Capillary Tube – Calibration Certificate |
| CV004-109 |
Cannon-Fenske Opaque size 400 |
240 – 1.200 cSt |
Glass |
1.2 |
Capillary Tube – Calibration Certificate |
| CV004-110 |
Cannon-Fenske Opaque size 450 |
500 – 2.500 cSt |
Glass |
2.5 |
Capillary Tube – Calibration Certificate |
| CV004-111 |
Cannon-Fenske Opaque size 500 |
1.600 – 8.000 cSt |
Glass |
8 |
Capillary Tube – Calibration Certificate |
| CV004-112 |
Cannon-Fenske Opaque size 600 |
4.000 – 20.000 cSt |
Glass |
20 |
Capillary Tube – Calibration Certificate |
| CV004-113 |
Cannon-Fenske Opaque size 650 |
9.000 – 45.000 cSt |
Glass |
45 |
Capillary Tube – Calibration Certificate |
| CV004-114 |
Cannon-Fenske Opaque size 700 |
20.000 – 100.000 cSt |
Glass |
100 |
Capillary Tube – Calibration Certificate |
CANNON-FENSKE ROUTINE
ASTM D-445-446, ASTM D2515, ISO 3104-3105 and UNE 400313 Cannon-Fenske Routine Viscometers quickly and easily measure the viscosities of transparent Newtonian liquids. Sample volume: aprox. 7 ml. Precision: ±0.2%. With constant value indication at +40 ºC and +100ºC.
| CODE |
DESCRIPTION |
VISCOSITY RANGE |
MATERIAL |
CONSTANT K APPROX. |
INCLUDED |
| CV004-201 |
cannon-Fenske routine size 25 |
0.5 – 2 cSt |
Glass |
0.002 |
Capillary Tube – Calibration Certificate |
| CV004-202 |
cannon-Fenske routine size 50 |
0.8 – 4 cSt |
Glass |
0.005 |
Capillary Tube – Calibration Certificate |
| CV004-203 |
cannon-Fenske routine size 75 |
1.6 – 8 cSt |
Glass |
0.008 |
Capillary Tube – Calibration Certificate |
| CV004-204 |
cannon-Fenske routine size 100 |
3 – 15 cSt |
Glass |
0.015 |
Capillary Tube – Calibration Certificate |
| CV004-205 |
cannon-Fenske routine size 150 |
7 – 35 cSt |
Glass |
0.035 |
Capillary Tube – Calibration Certificate |
| CV004-206 |
cannon-Fenske routine size 200 |
20 – 100 cSt |
Glass |
0.1 |
Capillary Tube – Calibration Certificate |
| CV004-207 |
cannon-Fenske routine size 300 |
50 – 200 cSt |
Glass |
0.25 |
Capillary Tube – Calibration Certificate |
| CV004-208 |
cannon-Fenske routine size 350 |
100 – 500 cSt |
Glass |
0.5 |
Capillary Tube – Calibration Certificate |
| CV004-209 |
cannon-Fenske routine size 400 |
240 – 1.200 cSt |
Glass |
1.2 |
Capillary Tube – Calibration Certificate |
| CV004-210 |
cannon-Fenske routine size 450 |
500 – 2.500 cSt |
Glass |
2.5 |
Capillary Tube – Calibration Certificate |
| CV004-211 |
cannon-Fenske routine size 500 |
1.600 – 8.000 cSt |
Glass |
8 |
Capillary Tube – Calibration Certificate |
| CV004-212 |
cannon-Fenske routine size 600 |
4.000 – 20.000 cSt |
Glass |
20 |
Capillary Tube – Calibration Certificate |
| CV004-213 |
cannon-Fenske routine size 650 |
9.000 – 45.000 cSt |
Glass |
45 |
Capillary Tube – Calibration Certificate |
| CV004-214 |
cannon-Fenske routine size 700 |
20.000 – 100.000 cSt |
Glass |
100 |
Capillary Tube – Calibration Certificate |