BAM-1022 Beta Attenuation Mass Monitor
Features:
- PM in-situ measurements with low measurement artefacts and good accuracy.
- Decreased frequency of background determination.
- Unmatched performance when operating at high ambient dew points.
- Remote operation and cloud-based communication are made possible by advanced communications features.
- Sophisticated diagnostics.
- Sensitivity is increased in comparison to previous in-line beta attenuation mass monitors.
- Weather data as well as data from other sensors.
Categories: Climatic/Environment Inspection, Particle Counter
Description
Specifications:
Measurement Principle: | Beta Attenuation |
US EPA Designations: | PM2.5 EPA Class III Federal Equivalent Method (EQPM-1013-209) |
Accuracy: | Meets US-EPA Requirements for Class III PM2.5 FEM |
Sampling Time: | Continuous Air Sampling with Hourly Tape Advance |
Measurement Cycles: | Primary: Automatic Hourly PM Measurement (Required for PM2.5 FEM Operation)
Secondary: User Selectable Short Term Averages (1, 5, 10, 15, or 30 minute) |
Sample Flow Rate: | 16.7 liters/minute |
Filter Tape: | Continuous glass fiber filter, 30mm x 21m roll. Up to 2 months operation per roll. |
Maintenance Interval: | 8 Weeks (minimum) |
Span Check: | Manual Audits Performed with Zero and Span Foils (Included) |
Beta Source: | 14C (carbon-14), 60 µCi ±15 µCi (2.22 MBq) |
Detector Type | Scintillation Photomultiplier Tube |
Operating Temperature Range: | -30° to +50° C |
Operating Humidity Range | 0 to 90% RH, non-condensing |
Enclosure | Instrument is integrated into its own weatherproof enclosure and sits on a separable, pump box |
Analog Output: | Two channels; optically isolated; switch settable voltage or current 0-1, 0-2.5, 0-5 VDC / 0-20, 2-20,
4-20 mA (Hourly Concentration and/or or User Selectable Short Term Average) |
Serial Interfaces: | 1 channel; full duplex RS-232, USB, and Ethernet serial (Shared common serial output). Baud rates
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 |
Compatible Software: | COMET™ (included), Air Plus™, terminal programs such as HyperTerminal® |
Data Logger Memory: | 11,827 records (1.4 years @ 1 record/hr. 8 days @ 1 record/min). |
Alarm Contact Closure: | 1 Channel; dry no contact; 1A at 125 VAC or 60 VDC Minimum |
Power Supply: | 100 – 230 VAC; 50/60 Hz universal AC power |
Power Consumption: | 300W (Incl. BAM-1022, Inlet Heater, BX-126 or BX-127 Pump, and Vent Fan) |
Approvals: | NRC, ISO-9001, ROHS, US-EPA |
Related products
Climatic/Environment Inspection
Air Flows Tester
Climatic/Environment Inspection
Climatic/Environment Inspection
Air Flows Tester
Climatic/Environment Inspection
Climatic/Environment Inspection
Climatic/Environment Inspection