Fungilab – VISCOLEAD SERIES ADV
Viscolead Adv
Measuring of advanced viscosity. Easy to use. 2 years of garantee
Category: Viscometer
Description
Main Features
SCREEN DATA | |
---|---|
Selected speed | rpm |
Selected spindle | SP |
Viscosity reading | cP (mPa·s) or cSt |
Percentatge of full scale | % |
Sampling temperature | ºC or ºF |
Shear Rate (with coaxial spindles) | SR (s-1) |
Shear Stress (with coaxial spindles) | SS (N/m2) |
Density (introduced by the user) | g/cm3 |
VISCOSITY READING | |
---|---|
Dynamic viscosity | cP or mPa·s |
Kinematic viscosity | cSt |
Units Converter | from SI to CGS |
PROGRAM FEATURES |
---|
Time to torque: Ending of the test upon reaching a programmed torque |
Time to stop: Ending of the test upon reaching a programmed time |
10 working memories |
OTHER MAIN FEATURES |
---|
AUTO-TEST with visual and resonant alarm |
AUTO-RANGE function |
Temperature Reading through PT100 probe |
User-enabled viscosity and temperature calibration |
10 language options |
Port: USB |
Software Datalogger: USB lets tranfer data to an Excel file in the PC |
Spindles
AISI 316 Stainless steel spindle, easily to identify according to its letter and number, in terms of the range of viscosity. Our units fulfills the next standards: These are the standards our units follow: BS: 6075, 5350
- BS: 6075, 5350
- ISO:2555,1652
- ASTM: 115, 789, 1076, 1084, 1286, 1417, 1439, 1638, 1824, 2196, 2336, 2364, 2393, 2556, 2669, 2849, 2983, 2994, 3232, 3236, 3716
Standard delivery
- The equipement is supplied complete with standard spindles
- 4 spindles for L model
- 6 spindles for R and H models
- Viscometer stand
- Spindle protector
- Temperature probe PT100
- Carring case
- USB cable
- Datalogger software
TECHNICAL SPECIFICATIONS
- Precision: +/- 1% full scale of range
- Resolution: For a minus viscosity of 10.000 cP : 0.1 cP For a major viscosity of 10.000 cP : 1 cP With the low viscosity adapter (LCP-LCP/B) : 0.01cP
- Repeatability: 0.2%
- Temperature probe features: Temperature limits: -10ºC to 150ºC 14ºF to 302ºF Resolution: 0.1ºC / -17.722 ºF Precision: +/- 0.2ºC / +/- 17.666 ºF Type of probe: PT100
- Supplied at 110-240VAC, 50/60 Hz.
ACCESSORIES
- APM : Small Sample Adapter with circulation jacket (without TL or TR spindles) Sample volume (6.7 – 13 ml.) Compatible with Brookfield viscometers
- APM/B : Small Sample Adapter without circulation jacket (without TL or TR spindles) Sample volume (6.7 – 13 ml.) Compatible with Brookfield viscometers
- LCP : Low Viscosity Adapter with circulation jacket (with spindle) Sample volume (16 ml.) Compatible with Brookfield viscometers
- LCP/B : Low Viscosity Adapter without circulation jacket (with spindle) Sample volume (16 ml.) Compatible with Brookfield viscometers
- HELDAL : Helix Drive Unit Accessory for measuring non-flowing substances viscosity (with spindles)
- THERMOSPHERE : Temperature control unit up to 300 ºC
CODE | MODEL | MEASURING RANGE (CP) | SPEED (R.P.M) | NUMBER OF SPEEDS |
---|---|---|---|---|
VL210003 | ADV L | *1 – 2.000.000 | 0.3 – 100 | 18 |
VL210002 | ADV R | 100 – 13.000.000 | 0.3 – 100 | 18 |
VL210001 | ADV H | 200 – 106.000.000 | 0.3 – 100 | 18 |
The viscosity range of the equipment is referenced between 0.01 and 100 rpm.
PPRFast spindle switch (push plug and release)
CODE | MODEL | MEASURING RANGE (CP) | SPEED (R.P.M) | NUMBER OF SPEEDS |
---|---|---|---|---|
VL211003* | ADV L + PPR | *1 – 2.000.000 | 0.3 – 100 | 18 |
VL211002* | ADV R + PPR | 25 – 13.000.000 | 0.3 – 100 | 18 |
VL211001* | ADV H + PPR | 200 – 106.000.000 | 0.3 – 100 | 18 |
The viscosity range of the equipment is referenced between 0.01 and 100 rpm.
Ranges
- (L) Low viscosity model
- (M) Medium viscosity model
- (H) High viscosity model
Low viscosity: The minimum viscosity when using a ‘L’ range with standard spindles is 10 cP * For measurements < 10cP, its recommended to use in conunction with the low viscosity adapter (LCP or LCP/B)
Related products
Viscometer
Viscometer
Viscometer
Viscometer
Viscometer